Murata LSM2 Series Single Output Non-Isolated POL DC/DC Converter Manual

This document describes the features and characteristics of the LSM2 series single output, non-isolated selectable-output POL DC/DC converters. They are suitable for distributed bus architectures with input ranges of 5V and 12V, and maximum outputs of 6A, 10A, or 16A. They are DOSA compatible and have phased start up sequencing and tracking, extensive self-protection, etc.


Murata LSM2 Series Single Output Non-Isolated POL DC/DC Converter Manual - cover page
Brand
Murata
Document type
User Manual
Language
English
Pages
17
File format
PDF
File size
1.3 MB
Published
07 May, 2012
Updated
28 September, 2023
Model
LSM2
MD5 checksum
2B0E10AD0787197B94A5C8A8D4D517FA

About this manual

The LSM2 Series are point‑of‑load (POL) DC/DC converters designed for distributed power architectures. They offer 5 V or 12 V wide input ranges and selectable single‑output voltages (3.3 V or 5 V) with up to 16 A of output current. Key features include phased start‑up sequencing, extensive self‑protection, remote sense for voltage drop compensation, and a compact SMT package that meets RoHS standards. The manual covers performance specifications, wiring, safety considerations, and application notes.

What's inside

  • Product Overview
  • Performance Specifications and Ordering Guide
  • Performance/Functional Specifications
  • Technical Notes
  • Input Fusing
  • Safety Considerations
  • Remote Sense
  • On/Off Control
  • Thermal Considerations
  • Environmental

Specifications

Input Voltage Range8.3‑14 V (12 V nominal) or 2.4‑5.5 V (5 V nominal)
Nominal Output Voltage5 V for D12 models, 3.3 V for W3 models
Maximum Output Current6 A, 10 A or 16 A depending on model
Efficiencyup to 95.8 %
Switching Frequency315 kHz (6 A models) or 230 kHz (10 A/16 A models)

Frequently asked questions

What is the input voltage range for the LSM2 converters?

The LSM2 converters accept 8.3‑14 V for the 12 V (D12) versions and 2.4‑5.5 V for the 5 V (W3) versions.

How does the remote sense function work?

Remote sense provides point‑of‑use regulation by compensating voltage drops up to 10 % of the output voltage, improving accuracy for distributed wiring.

What is the maximum output current for the 6 A model?

The 6 A version can deliver up to 6 A of continuous output current.