Agilent HEDM-550x/560x Optical Encoder Technical Data

This document describes the technical data and features of the Quick Assembly Two and Three Channel Optical Encoders. These encoders have two or three channels and support quadrature output with optional index pulse. Features include quick and easy assembly, no signal adjustment required, availability of external mounting ears, low cost, resolutions up to 1024 counts per revolution, small size, operating temperature range of -40°C to 100°C, TTL compatibility, and single 5V supply.


Agilent HEDM-550x/560x Optical Encoder Technical Data - cover page
Brand
Agilent
Category
Other device
Document type
Datasheet
Language
English
Pages
15
File format
PDF
File size
291 KB
Published
04 May, 2012
Updated
29 September, 2023
MD5 checksum
80A48B80A6AABB9284DB9897E7F3AD83

About this manual

The Agilent HEDM-550x/560x series are low‑cost two‑channel optical incremental encoders with optional external mounting ears. They provide high reliability, up to 1024 counts per revolution, and operate over a wide temperature range.

The document includes features, mechanical dimensions, electrical characteristics, recommended operating conditions, and mounting guidelines for quick assembly onto motor shafts.

What's inside

  • Features
  • Description
  • Applications
  • Package Dimensions
  • Theory of Operation
  • Absolute Maximum Ratings
  • Recommended Operating Conditions
  • Electrical Characteristics
  • Mechanical Characteristics
  • Mounting Considerations

Specifications

ResolutionUp to 1024 counts per revolution
Operating Temperature-40°C to 100°C
Supply Voltage4.5 V to 5.5 V
Maximum Speed30,000 RPM
High Level Output Voltage2.4 V
Output Current per Channel-1.0 mA to 5 mA

Frequently asked questions

What is the operating temperature range?

The encoders operate from –40 °C to +100 °C.

What is the maximum resolution of the HEDM‑550x/560x series?

They can resolve up to 1024 counts per revolution.

What supply voltage is required?

A supply voltage of 4.5 V to 5.5 V is recommended.

How many channels does the HEDM‑550x/560x provide?

The HEDM series provides two quadrature channels; it does not include a third‑channel index output.