The STARTSP14N001 LCD starter kit from Hitachi Europe provides the means to interface a customer system to Hitachi SP14N001, SP14N001-ZZA, SP14N001-Z1 or SP14N001-Z1A LCD modules. The kit includes an INVC191 CFL inverter, a CFL inverter input cable with flying leads, a flexible printed circuit adapter cable, and reference documents including the inverter specification, LCD handling precautions, an LCD controller reference list and a connector supplier list.
The assembly instructions describe attaching the display module CFL connector to the inverter output, connecting the inverter input cable, and wiring the flying leads to power according to the CFL inverter specification. The flexible printed circuit adapter cable is inserted into the top contact ZIF connector on the LCD module, and the correct signals are connected to its through holes according to the display specification and pin assignment. Important notes cover the power-up sequence, inverter fuse failure if power is applied without a CFL connected, and high voltages on the powered inverter board.
| Compatible LCD modules | SP14N001, SP14N001-ZZA, SP14N001-Z1, SP14N001-Z1A |
|---|---|
| Included CFL inverter | INVC191 |
It is used to interface a system to Hitachi SP14N001, SP14N001-ZZA, SP14N001-Z1 or SP14N001-Z1A LCD modules.
This will result in inverter fuse failure.
It is inserted into the top contact ZIF connector on the LCD module after gently pulling the retaining bar to release it.