Analog Devices ADCLK905/ADCLK907/ADCLK925 Clock/Data Buffer Datasheet

The ADCLK905/ADCLK907/ADCLK925 are ultrafast SiGe ECL clock/data buffers. They feature a propagation delay of 95 ps, a toggle rate of 7.5 GHz, a typical output rise/fall time of 60 ps, and a random jitter of 60 fs. They are suitable for clock and data signal restoration and level shifting, automated test equipment (ATE), high-speed instrumentation, high-speed line receivers, and converter clocking applications.


Analog Devices ADCLK905/ADCLK907/ADCLK925 Clock/Data Buffer Datasheet - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
16
File format
PDF
File size
1.1 MB
Published
03 May, 2012
Updated
28 September, 2023
MD5 checksum
594FD851262DDE7C45905031793B098C

About this manual

The ADCLK905, ADCLK907 and ADCLK925 are ultrafast SiGe clock/data buffers offering full‑swing ECL output drivers. They support both PECL and NECL operation, provide on‑chip terminations, and are available in 16‑lead LFCSP packages.

Key features include 95 ps typical propagation delay, 7.5 GHz toggle rate, 60 fs random jitter, a supply range of 2.5 V‑3.3 V, and an industrial temperature range from –40 °C to +125 °C. The document provides electrical characteristics, pin configurations, typical application circuits, and performance graphs.

What's inside

  • Features
  • Applications
  • General Description
  • Typical Application Circuits
  • Specifications
  • Electrical Characteristics
  • Absolute Maximum Ratings
  • Thermal Resistance
  • Pin Configurations and Function Descriptions
  • Typical Performance Characteristics

Specifications

Propagation Delay (typical)95 ps
Toggle Rate7.5 GHz
Random Jitter (RMS)60 fs
Supply Voltage2.5 V – 3.3 V
Operating Temperature Range-40 °C – +125 °C
Input High‑Level Voltage1.6 V
Output Differential Voltage610 mV – 1040 mV

Frequently asked questions

What is the typical propagation delay of the ADCLK buffers?

The typical propagation delay is 95 ps.

What temperature range can the ADCLK devices operate in?

They operate from –40 °C up to +125 °C.

What supply voltage does the ADCLK905/907/925 require?

The devices require a supply voltage between 2.5 V and 3.3 V.

What is the maximum toggle rate of these buffers?

The maximum toggle rate is 7.5 GHz.