3M 963/963E Benchtop Air Ionizer Manual

3M™ Benchtop Air Ionizers 963/963E are designed to generate and deliver a stream of ionized air. Its intended use is to neutralize excess static electricity buildup on electronic devices and work surfaces.


3M 963/963E Benchtop Air Ionizer Manual - cover page
Brand
3M
Category
Other
Document type
User Manual
Language
English
Pages
6
File format
PDF
File size
1.2 MB
Published
09 April, 2012
Updated
30 September, 2023
MD5 checksum
275B4BF046E2508E93631A7971E3B914

About this manual

This manual describes the 3M™ Benchtop Air Ionizers 963/963E, self‑contained ionizing air blowers that neutralize static electricity on electronic devices and work surfaces. It covers intended use, safety warnings, performance specifications, power requirements, installation steps, operation controls, and routine maintenance.

The document also includes procedures for performance verification, physical characteristics, and warranty information, helping users ensure the ionizer operates within specified limits and remains safe to use.

What's inside

  • Safety Information
  • Description
  • Performance
  • Power Requirements
  • Installation
  • Operation
  • Maintenance
  • Performance Verification
  • Physical Characteristics

Specifications

Power rating (963 model)AC 120V 60Hz, 0.2 A, 20 W
Power rating (963E model)DC 24V, 0.42 A, 10 W
Power inlet (963 model)IEC 320 socket with 6 ft cord
Power inlet (963E model)Mini DIN socket with universal power supply
Dimensions (with mounting base)7 in W × 9 in H × 4 in D (18 cm W × 23 cm H × 10 cm D)
Weight2.5 lb (1.1 kg)
Static discharge time (963)< 1 second at 1 ft

Frequently asked questions

What power source does the 963 model require?

The 963 ionizer requires AC 120 V power and is supplied with a 6 ft power cord and a North American three‑prong plug.