Intersil X9C102 Datasheet

This document is a function introduction document for X9C102, X9C103, X9C104, X9C503


Intersil X9C102 Datasheet - cover page
Brand
Intersil
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
11
File format
PDF
File size
207 KB
Published
27 March, 2012
Updated
30 September, 2023
Model
X9C102
MD5 checksum
E53F4F50718CD6FBE954AE3F63F627C5

About this manual

The X9C102 series are Intersil digitally controlled potentiometers (xDCP™) featuring a 99‑element resistor array, 100 wiper tap points, and non‑volatile memory to retain the wiper position on power‑up. The device is controlled via a three‑wire serial interface (CS, INC, U/D) and can operate as a three‑terminal potentiometer or a two‑terminal variable resistor.

The datasheet details absolute maximum ratings, recommended operating conditions, electrical characteristics, package dimensions for 8‑lead SOIC and PDIP versions, and programming procedures for storing and recalling the wiper position.

What's inside

  • Description
  • Features
  • Pin Configuration
  • Ordering Information
  • Absolute Maximum Ratings
  • Recommended Operating Conditions
  • DC Operating Characteristics
  • AC Operating Characteristics
  • Instructions and Programming
  • Package Information

Specifications

Wiper tap points100
Resistive elements99
Active current (max)3 mA
Standby current (max)750 µA
Operating temperature (industrial)-40 °C to +85 °C
Endurance (data changes per bit)100 000
Data retention100 years
Wiper resistance100 Ω
Package types8‑lead SOIC and 8‑lead PDIP

Frequently asked questions

What interface is used to control the X9C102?

The device is controlled by a three‑wire serial interface using the CS, INC, and U/D pins.

How many wiper positions are available on the X9C102?

The potentiometer provides 100 wiper tap points.

What is the maximum standby current of the X9C102?

The standby current is specified as up to 750 µA.

What temperature range can the X9C102 operate in for industrial applications?

It operates from –40 °C to +85 °C in industrial environments.