HF-R TD 1 14-17 PL-R EII 220-240V is a flat, lightweight high-frequency electronic ballast that uses DALI (digital addressable lighting interface) or touch dimming button protocol for PL-T/C/R fluorescent lamps. HF- REGULATORII ballast uses Philips' new EII technology, which provides full digital input (power) and output (light source) management.
The HF-RTD1 is a high‑frequency electronic ballast that supports DALI or touch‑dim control for PL‑T, PL‑C and PL‑R fluorescent lamps. It offers digital input and output management and complies with multiple safety and EMC standards.
The sheet lists key electrical parameters such as a line voltage of 220‑240 V, operating frequency up to 80 kHz, and a maximum power loss of 0.35 W. Physical dimensions are 123 mm × 79 mm × 33 mm and the unit weighs 0.195 kg. Temperature limits, surge protection, and over‑voltage protection values are also provided. This manual is written in Chinese.
| Line voltage | 220‑240 V |
|---|---|
| Line frequency | 50/60 Hz |
| Maximum power loss | 0.35 W |
| Peak factor (max) | 17 |
| Trigger time (max) | 0.2 s |
| Working frequency (max) | 80 kHz |
| Net weight | 0.195 kg |
| Operating temperature range | 0 °C to 50 °C (trigger), –20 °C to 50 °C (ambient) |
It is rated for 220‑240 V line voltage.
The ballast can operate up to 80 kHz.