Error codeOV
Overvoltage means the deceleration time is too short or the supply voltage is too high. The manual's first action is: “Extend deceleration time or connect a braking resistor (braking resistor unit).”
- Model
- Yaskawa VARISPEED-616G5
- Display shows
- Overvoltage (OV)
- Type
- Error code
- Source
- Manual p. 274
What OV means
Overvoltage p. 274
Common causes
- Deceleration time is too short, resulting in excessive regenerated energy from the motor. p. 274
- Supply voltage is too high. p. 274
What to do
- Extend deceleration time or connect a braking resistor (braking resistor unit). p. 274
- Reduce the voltage to within the power supply specifications. p. 274
Before you service the product, read the safety instructions in the manual p. 4.
If OV is still not resolved
This page summarises what the manufacturer’s manual says about OV; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.