YASKAWA III series SGM/SGDS Error A.520: Vibration alarm

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Alarm codeA.520

Vibration alarm means abnormal motor speed vibration is detected. The manual's first action is: “DB stop.”

Model
YASKAWA III series SGM/SGDS
Display shows
Vibration alarm (A.520)
Type
Alarm code
Source
Manual p. 289

What A.520 means

Vibration alarm p. 289

Common causes

  • Abnormal motor speed vibration detected. p. 289
  • Occurs during motor operation. p. 289
  • The inertia ratio (Pn103) value is larger than the actual value or has changed significantly. p. 289

What to do

  1. DB stop. p. 289
  2. Abnormal motor speed vibration detected. p. 289
  3. Set the inertia ratio (Pn103) correctly. p. 289

Before you service the product, read the safety instructions in the manual p. 292.

If A.520 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A.520; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.