Fault codeA.710
Overload (instantaneous maximum load) means running with a torque far exceeding the rated value for several seconds to several tens of seconds. The manual's first action is: “Zero-speed stop”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- Overload (instantaneous maximum load) (A.710)
- Type
- Fault code
- Source
- Manual p. 289
What A.710 means
Overload (instantaneous maximum load) p. 289
Common causes
- Running for several seconds to several tens of seconds with a torque far exceeding the rated value p. 289
- Occurs when the control power is turned on p. 289
- Occurs while the servo is ON p. 289
What to do
- Zero-speed stop p. 289
- Servo unit circuit board fault – replace the servo unit p. 289
- Motor wiring abnormality (poor wiring or bad connections) – correct the motor wiring p. 289
- Encoder wiring abnormality (poor wiring or bad connections) – correct the encoder wiring p. 289
- Servo unit fault – replace the servo unit p. 289
Before you service the product, read the safety instructions in the manual p. 292.
If A.710 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A.710; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.