Alarm code4334
The converter has experienced an overvoltage condition. The manual's first action is: “(1)Reset the alarm.”
- Model
- Yaskawa FS100
- Display shows
- OVERVOLTAGE (CONVERTER) (4334)
- Type
- Alarm code
- Source
- Manual p. 225
What 4334 means
OVERVOLTAGE (CONVERTER) p. 225
Common causes
- Sub Code: Signifies the physical No. of converter in which the alarm occurred p. 225
- Setting error p. 225
- Voltage failure p. 225
What to do
- (1)Reset the alarm. p. 225
- (2)If the alarm occurs again, check that U-, V- and W-phase are appropriately connected. p. 225
- Check the following settings. -The tools or the mass of the workpieces p. 225
- Modify the primary breaker voltage to the specified voltage 200V(+10% to 15%). p. 225
If 4334 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.
This page summarises what the manufacturer’s manual says about 4334; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.