Yaskawa FS100 Error 4324: CONVERTER OVERLOAD

Yaskawa FS100 · taken from the manufacturer’s manual, pages cited

Alarm code4324

The converter has overloaded due to incorrect settings or hardware failure. The manual's first action is: “Check the settings of the following. -If the tool or the workpiece used has exceeded the allowable load.”

Model
Yaskawa FS100
Display shows
CONVERTER OVERLOAD (4324)
Type
Alarm code
Source
Manual p. 222

What 4324 means

CONVERTER OVERLOAD p. 222

Common causes

What to do

  1. Check the settings of the following. -If the tool or the workpiece used has exceeded the allowable load. p. 222
  2. Adjust the job speed. Adjust the acceleration/deceleration of ACC and DEC instructions. p. 222
  3. (1)Reset the alarm. (2)If the alarm occurs again, replace controller. Save the CMOS BIN before replace controller to be safe. p. 222

If 4324 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about 4324; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.