Shihlin Electric SDA Series Error AL. 02: Low voltage

AC servo system · taken from the manufacturer’s manual, pages cited

Alarm codeAL. 02

AL.02 means main loop input voltage is too low or there's no input voltage source or incorrect power system. The manual's first action is: “Power OFF→ON”

Model
Shihlin Electric SDA Series
Display shows
Low voltage (AL. 02)
Type
Alarm code
Source
Manual p. 198

What AL. 02 means

Low voltage p. 229

Common causes

  • Main loop input voltage is lower than the rated permissive voltage p. 229
  • Main loop input voltage has no input voltage source p. 229
  • Power source input error (incorrect power source system) p. 229

What to do

  1. Power OFF→ON p. 229
  2. Press SET at the current alarm screen p. 229
  3. Alarm reset (RES) signal p. 229
  4. Check if the main loop input voltage wiring is normal. Reconfirm the voltage wiring. p. 229
  5. Use a voltmeter to check if the main loop voltage is normal. Reconfirm the power source switch. p. 229
  6. Use a voltmeter to assess if the power source system meets the specification. Use a correct voltage source or a serial voltage stabilizer. p. 229

If AL. 02 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.

This page summarises what the manufacturer’s manual says about AL. 02; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.