Alarm codeAL. 02
AL.02 means main loop input voltage is too low or there's no input voltage source or incorrect power system. The manual's first action is: “Power OFF→ON”
- Model
- Shihlin Electric SDA Series
- Display shows
- Low voltage (AL. 02)
- Type
- Alarm code
- Source
- Manual p. 198
What AL. 02 means
Low voltage p. 229
Common causes
- Main loop input voltage is lower than the rated permissive voltage p. 229
- Main loop input voltage has no input voltage source p. 229
- Power source input error (incorrect power source system) p. 229
What to do
- Power OFF→ON p. 229
- Press SET at the current alarm screen p. 229
- Alarm reset (RES) signal p. 229
- Check if the main loop input voltage wiring is normal. Reconfirm the voltage wiring. p. 229
- Use a voltmeter to check if the main loop voltage is normal. Reconfirm the power source switch. p. 229
- Use a voltmeter to assess if the power source system meets the specification. Use a correct voltage source or a serial voltage stabilizer. p. 229
If AL. 02 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.
This page summarises what the manufacturer’s manual says about AL. 02; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.