Alarm codeAL. 05
AL.05 means overload occurred due to exceeding rated load, incorrect parameter setup, or system instability. The manual's first action is: “Power OFF→ON”
- Model
- Shihlin Electric SDA Series
- Display shows
- Overload (AL. 05)
- Type
- Alarm code
- Source
- Manual p. 198
What AL. 05 means
Overload p. 229
Common causes
- Continue usage when exceeding the actuator rated load p. 229
- Control system parameter setup p. 229
- Unstable system p. 229
- Position encoder, motor wiring error p. 229
What to do
- Power OFF→ON p. 229
- Press SET at the current alarm screen p. 229
- Alarm reset (RES) signal p. 229
- Check if the overload is too large. Increase the motor capacity or decrease the load. p. 229
- Check if there is any machine vibration. Make acceleration / deceleration auto-tuning. p. 229
- The set acceleration / deceleration constant is too fast. Slow down the acceleration / deceleration set time. p. 229
- Check the wiring of U, V, W, and position encoder. Making correct wiring. p. 229
If AL. 05 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.
This page summarises what the manufacturer’s manual says about AL. 05; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.