Alarm codeAL. 0A
AL.0A indicates no communication commands were received for too long or the overtime constant is improperly set. The manual's first action is: “Power OFF→ON”
- Model
- Shihlin Electric SDA Series
- Display shows
- Serial communication overtime (AL. 0A)
- Type
- Alarm code
- Source
- Manual p. 198
What AL. 0A means
Serial communication overtime p. 229
Common causes
- Did not receive communication commands for a long time p. 229
- Improper setup of the overtime constant p. 229
What to do
- Power OFF→ON p. 229
- Press SET at the current alarm screen p. 229
- Alarm reset (RES) signal p. 229
- Check if the communication line if broken or loosen. Change or renew the connection. p. 229
- Check the setup of the overtime constant. Set the values correctly. p. 229
If AL. 0A is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.
This page summarises what the manufacturer’s manual says about AL. 0A; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.