Alarm codeAL. 10
AL.10 indicates a malfunction in the power transistor due to mechanical impacts, motor connection error, or vibration. The manual's first action is: “Power OFF→ON”
- Model
- Shihlin Electric SDA Series
- Display shows
- Abnormal power transistor (AL. 10)
- Type
- Alarm code
- Source
- Manual p. 198
What AL. 10 means
Abnormal power transistor p. 229
Common causes
- Mechanical impacts p. 229
- Motor connection error p. 229
- System operated under vibration p. 229
- Encoder breakdown p. 229
What to do
- Power OFF→ON p. 229
- Press SET at the current alarm screen p. 229
- Alarm reset (RES) signal p. 229
- Check if the route planning is problematic. p. 229
- Check motor connection p. 229
- Check if the machine has high frequency noises. p. 229
- Check if the encoder is normal. p. 229
If AL. 10 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.
This page summarises what the manufacturer’s manual says about AL. 10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.