Shihlin Electric SDA Series Error AL. 10: Abnormal power transistor

AC servo system · taken from the manufacturer’s manual, pages cited

Alarm codeAL. 10

AL.10 indicates a malfunction in the power transistor due to mechanical impacts, motor connection error, or vibration. The manual's first action is: “Power OFF→ON”

Model
Shihlin Electric SDA Series
Display shows
Abnormal power transistor (AL. 10)
Type
Alarm code
Source
Manual p. 198

What AL. 10 means

Abnormal power transistor p. 229

Common causes

  • Mechanical impacts p. 229
  • Motor connection error p. 229
  • System operated under vibration p. 229
  • Encoder breakdown p. 229

What to do

  1. Power OFF→ON p. 229
  2. Press SET at the current alarm screen p. 229
  3. Alarm reset (RES) signal p. 229
  4. Check if the route planning is problematic. p. 229
  5. Check motor connection p. 229
  6. Check if the machine has high frequency noises. p. 229
  7. Check if the encoder is normal. p. 229

If AL. 10 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.

This page summarises what the manufacturer’s manual says about AL. 10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.