Alarm codeAL. 07
AL.07 means the pulse command frequency exceeds rated input or the device is broken. The manual's first action is: “Power OFF→ON”
- Model
- Shihlin Electric SDA Series
- Display shows
- Abnormal pulse control command (AL. 07)
- Type
- Alarm code
- Source
- Manual p. 198
What AL. 07 means
Abnormal pulse control command p. 229
Common causes
- Pulse command frequency higher than the rated input frequency p. 229
- Input pulse command device breakdowns p. 229
What to do
- Power OFF→ON p. 229
- Press SET at the current alarm screen p. 229
- Alarm reset (RES) signal p. 229
- Use pulse frequency measurer to assess the input frequency. p. 229
- Change the input pulse command device. p. 229
If AL. 07 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.
This page summarises what the manufacturer’s manual says about AL. 07; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.