Shihlin Electric SDA Series Error AL. 07: Abnormal pulse control command

AC servo system · taken from the manufacturer’s manual, pages cited

Alarm codeAL. 07

AL.07 means the pulse command frequency exceeds rated input or the device is broken. The manual's first action is: “Power OFF→ON”

Model
Shihlin Electric SDA Series
Display shows
Abnormal pulse control command (AL. 07)
Type
Alarm code
Source
Manual p. 198

What AL. 07 means

Abnormal pulse control command p. 229

Common causes

  • Pulse command frequency higher than the rated input frequency p. 229
  • Input pulse command device breakdowns p. 229

What to do

  1. Power OFF→ON p. 229
  2. Press SET at the current alarm screen p. 229
  3. Alarm reset (RES) signal p. 229
  4. Use pulse frequency measurer to assess the input frequency. p. 229
  5. Change the input pulse command device. p. 229

If AL. 07 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.

This page summarises what the manufacturer’s manual says about AL. 07; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.