Alarm codeAL. 06
AL.06 indicates overspeed from high pulse frequency, improper acceleration/deceleration time, or servo instability. The manual's first action is: “Power OFF→ON”
- Model
- Shihlin Electric SDA Series
- Display shows
- Overspeed (AL. 06)
- Type
- Alarm code
- Source
- Manual p. 198
What AL. 06 means
Overspeed p. 229
Common causes
- Over high input frequency of the pulse command p. 229
- Incorrect setup of the acceleration / deceleration time parameter p. 229
- A too large overshoot caused by unstable servo system p. 229
What to do
- Power OFF→ON p. 229
- Press SET at the current alarm screen p. 229
- Alarm reset (RES) signal p. 229
- Check if the input frequency of the pulse command is too high. Correctly set the pulse frequency. p. 229
- Check if the acceleration / deceleration time constant is too small. Increase the acceleration / deceleration time constant. p. 229
- Observe if the system vibrate constantly. 1. Adjust the gain to a suitable value. 2. If adjusting the gain value is not effective, use the following method. (a) Minimize the load inertia. (b) Change the acceleration / deceleration time constant. p. 229
If AL. 06 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.
This page summarises what the manufacturer’s manual says about AL. 06; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.