Shihlin Electric SDA Series Error AL. 06: Overspeed

AC servo system · taken from the manufacturer’s manual, pages cited

Alarm codeAL. 06

AL.06 indicates overspeed from high pulse frequency, improper acceleration/deceleration time, or servo instability. The manual's first action is: “Power OFF→ON”

Model
Shihlin Electric SDA Series
Display shows
Overspeed (AL. 06)
Type
Alarm code
Source
Manual p. 198

What AL. 06 means

Overspeed p. 229

Common causes

  • Over high input frequency of the pulse command p. 229
  • Incorrect setup of the acceleration / deceleration time parameter p. 229
  • A too large overshoot caused by unstable servo system p. 229

What to do

  1. Power OFF→ON p. 229
  2. Press SET at the current alarm screen p. 229
  3. Alarm reset (RES) signal p. 229
  4. Check if the input frequency of the pulse command is too high. Correctly set the pulse frequency. p. 229
  5. Check if the acceleration / deceleration time constant is too small. Increase the acceleration / deceleration time constant. p. 229
  6. Observe if the system vibrate constantly. 1. Adjust the gain to a suitable value. 2. If adjusting the gain value is not effective, use the following method. (a) Minimize the load inertia. (b) Change the acceleration / deceleration time constant. p. 229

If AL. 06 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.

This page summarises what the manufacturer’s manual says about AL. 06; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.