Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
AC drive under-temperature (fault) happens when the heatsink or power board temperature is too low for normal operation. The manual's first action is: “The ambient temperature is too low for the drive. Move the drive …
Output phase supervision fault occurs when no current is detected in one motor phase, indicating a motor cable or filter issue. The manual's first action is: “Do a check of the motor cable and the motor.”
Input phase fault arises from supply voltage malfunction, defective fuse, faulty cables, or insufficient load for supervision to work. The manual's first action is: “Do a check of the supply voltage, the fuses and sup…
Undervoltage (fault) occurs when DC link voltage drops below limits, supply voltage is too low, or a component is defective. The manual's first action is: “If there is a temporary supply voltage break, reset the fault…
Saturation fault happens due to defective IGBT de-saturation, short circuit, or overload in the brake resistor. The manual's first action is: “This fault cannot be reset from the control panel. Make a power down of th…
Charging switch fault occurs when the charging switch is closed but feedback information indicates it is OPEN. The manual's first action is: “Reset the fault and restart the drive. Do a check of the feedback signal an…
Earth fault (hardware fault) is triggered when the sum of motor phase currents is not zero as measured. The manual's first action is: “Do a check of the motor cables and the motor. Do a check of the filters.”
Overvoltage (hardware fault) happens when the DC-link voltage exceeds its limits. The manual's first action is: “Set the deceleration time longer [P3.4.1.3 and P3.4.2.3]. Activate the overvoltage controller. Do a chec…
Overcurrent (hardware fault) occurs when the motor cable carries too high a current (>4*H). The manual's first action is: “Do a check of the loading. Do a check of the motor. Do a check of the cables and connections.”
All 39 error codes of the Vacon 100 Flow Vacon 100 Flow drive with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
Sensor cleaning could not be performed. The manual's first action is: “Operate the power switch (p.47).”
Cannot save images because card is full. The manual's first action is: “Replace the card, erase unnecessary images, or format the card (p.43, 430, 70).”
Card cannot be accessed. The manual's first action is: “Remove and insert the card again, replace the card, or format the card with the camera (p.43, 70).”
Communications between the camera and lens is faulty. The manual's first action is: “Clean the electrical contacts on the camera and lens. Use a genuine Canon lens, or remove and install the battery again (p.27, 42).”
All 4 error codes of the Canon EOS 6D Mark II Canon EOS 6D Mark II with their meaning, causes and what to do, taken from the manufacturer's manual with page references.