Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Motor Hall Signal Abnormality indicates a problem with motor signal detection. The manual lists no action for this code.
Throttle Abnormality indicates an issue with the throttle system. The manual lists no action for this code.
All 5 error codes of the KT KT-LCD 10Y KT KT-LCD 10Y with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
The stored data integrity has failed due to a mismatch in the CRC code during retrieval. The manual's first action is: “If there is a mismatch, then this alarm is generated.”
The calculated energy value from calibration analysis does not match the certified energy value. The manual lists no action for this code.
Stream 4 RF is out of order due to incorrect thermal conductivity response factor ordering for natural gas applications. The manual lists no action for this code.
Stream (1, 2, or 3) Out Of Order indicates streams should be set to Analysis or Unused only. The manual lists no action for this code.
The GC has computed an invalid energy value for the calibration gas. The manual's first action is: “The GC then compares this value to the Cal Gas Cert CV and determines if the calibration gas's energy value is within…
The GC's component data table does not match the replacement module's component data table. The manual's first action is: “The component data table of the GC must match (with the exception of neo-pentane) the componen…
Stream 4 RF Deviation code indicates a calibration run changed component response factor by more than the set percentage. The manual lists no action for this code.
Stream (1, 2, or 3) RF Deviation alarm indicates streams are incorrectly configured for calibration. The manual's first action is: “Start MON2020 and select Streams on the Application menu.”
The analysis of the validation gas for the associated stream is outside the allowable percent deviation, as defined in the Validation Data table. The manual's first action is: “Confirm that the validation gas concentr…
Analog input or output signal is outside the allowed range for the analog output. The manual's first action is: “If the value is valid, re-range the analog output and the associated device that is receiving the signal…
The carrier gas pressure is outside the acceptable range as measured by the analytical module's sensor. The manual's first action is: “Verify that the regulated pressure at the bottle is at 90 psig (6.2 BarG).”
All 11 error codes of the Rosemount 370XA Rosemount 370XA gas chromatograph with their meaning, causes and what to do, taken from the manufacturer's manual with page references.