Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Sensor check. No conductivity display. Possible reasons: Sensor in air, Sensor defective. The manual's first action is: “Remedy: Check sensor installation, Replace sensor”
Alarm, sensor or glass limit value exceeded. Impedance of glass membrane too high. The manual's first action is: “Remedy: Check pH sensor, replace if necessary, Check glass limit value and correct if necessary, Replac…
Sensor reference alarm. Impedance of reference too low. The manual's first action is: “Remedy: Inspect glass electrode for hair-line cracks and breakage, Check the medium temperature, Check the electrode plug-in head …
Sensor glass breakage alarm. Impedance of glass membrane too low. The manual's first action is: “Remedy: Inspect glass electrode for hair-line cracks and breakage, Check the medium temperature, Check the electrode plu…
No sensor communication. The manual's first action is: “Possible reasons: No sensor connection, Faulty sensor connection, Short-circuit in the sensor cable, Short-circuit in the neighboring channel, Sensor firmware up…
Sensor connection. The manual's first action is: “Replace sensor Contact service”
Sensor electronics defective. The manual's first action is: “Replace sensor Contact service”
Incorrect sensor type. The manual's first action is: “Switch to a sensor of the configured type.”
The sensor data could not be written. The manual's first action is: “Repeat writing of the sensor data Replace sensor”
Sensor data invalid. The manual's first action is: “Update date of the transmitter Replace sensor”
All 22 error codes of the Endress+Hauser CM14 CM14 transmitter with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
Temperature error. DLC-C2P6-D-E is too hot and has switched off to protect itself. The manual lists no action for this code.
Output current is too high. The manual lists no action for this code.
More current is being output than should be, so DLC-C2P6-D-E has turned off outputs. The manual's first action is: “This may be caused by hardware error. Check with your distributor.”
There is not enough supply voltage for requested output current. The manual lists no action for this code.