Mitsubishi Electric MDS-C1 Series Error 7F: Power reboot request

AC Servo/Spindle · taken from the manufacturer’s manual, pages cited

Error code7F

Power reboot request alarm is triggered by a mismatch in program mode selection or high-gain parameters during startup. The manual's first action is: “Turn the drive unit power ON again.”

Model
Mitsubishi Electric MDS-C1 Series
Display shows
Power reboot request (7F)
Type
Error code
Source
Manual p. 313

What 7F means

Power reboot request p. 313

Common causes

  • A mismatch in the program mode selection was detected. p. 313
  • This alarm is detected if the high-gain specification parameters are set when the drive unit is started up with the standard specification software mode, or if the standard specification parameters are set when started up with the high-gain specifications. p. 313

What to do

  1. Turn the drive unit power ON again. p. 313
  2. Turn the drive unit's control power ON again. p. 313

Before you service the product, read the safety instructions in the manual p. 4.

If 7F is still not resolved

  • contact service / dealer p. 5
    “Wiring, maintenance and inspection work must be done by a qualified technician.”

This page summarises what the manufacturer’s manual says about 7F; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.