Error code89
Detector converter unit 2 connection error means an error was detected in the connection with the analog output linear scale for the servo or initial communication failure with the MDS-B-PJEX spindle. The manual's first action is: “PR”
- Model
- Mitsubishi Electric MDS-C1 Series
- Display shows
- Detector converter unit 2 connection error (89)
- Type
- Error code
- Source
- Manual p. 313
What 89 means
Detector converter unit 2 connection error p. 313
Common causes
- With the servo, an error was detected in the connection with the analog output linear scale for the MDS-B-HR unit. With the spindle, initial communication with the MDS-B-PJEX was not possible. p. 313
- The version was changed. p. 313
- The version was not changed. p. 313
- The alarm is always repeated. The state is returned to normal once, but then the alarm occurs occasionally. p. 313
- No abnormality is found in particular. p. 313
- The connector is disconnected (or loose). p. 313
- The connector is not disconnected. p. 313
What to do
- PR p. 313
- Replace with a drive unit containing the original software version. p. 313
- Investigate item 2. p. 313
- Replace the drive unit. p. 313
- Correctly install. p. 313
- Servo : Investigate item 2. Spindle : Investigate item 4. p. 313
Before you service the product, read the safety instructions in the manual p. 4.
If 89 is still not resolved
- contact service / dealer p. 5 “Wiring, maintenance and inspection work must be done by a qualified technician.”
This page summarises what the manufacturer’s manual says about 89; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.