Mitsubishi Electric MDS-C1 Series Error 89: Detector converter unit 2 connection error

AC Servo/Spindle · taken from the manufacturer’s manual, pages cited

Error code89

Detector converter unit 2 connection error means an error was detected in the connection with the analog output linear scale for the servo or initial communication failure with the MDS-B-PJEX spindle. The manual's first action is: “PR”

Model
Mitsubishi Electric MDS-C1 Series
Display shows
Detector converter unit 2 connection error (89)
Type
Error code
Source
Manual p. 313

What 89 means

Detector converter unit 2 connection error p. 313

Common causes

  • With the servo, an error was detected in the connection with the analog output linear scale for the MDS-B-HR unit. With the spindle, initial communication with the MDS-B-PJEX was not possible. p. 313
  • The version was changed. p. 313
  • The version was not changed. p. 313
  • The alarm is always repeated. The state is returned to normal once, but then the alarm occurs occasionally. p. 313
  • No abnormality is found in particular. p. 313
  • The connector is disconnected (or loose). p. 313
  • The connector is not disconnected. p. 313

What to do

  1. PR p. 313
  2. Replace with a drive unit containing the original software version. p. 313
  3. Investigate item 2. p. 313
  4. Replace the drive unit. p. 313
  5. Correctly install. p. 313
  6. Servo : Investigate item 2. Spindle : Investigate item 4. p. 313

Before you service the product, read the safety instructions in the manual p. 4.

If 89 is still not resolved

  • contact service / dealer p. 5
    “Wiring, maintenance and inspection work must be done by a qualified technician.”

This page summarises what the manufacturer’s manual says about 89; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.