Mitsubishi Electric MDS-C1 Series Error 76: External emergency stop setting error

AC Servo/Spindle · taken from the manufacturer’s manual, pages cited

Error code76

External emergency stop setting error occurs when rotary switch settings mismatch parameter settings. The manual's first action is: “AR”

Model
Mitsubishi Electric MDS-C1 Series
Display shows
External emergency stop setting error (76)
Type
Error code
Source
Manual p. 312

What 76 means

External emergency stop setting error p. 312

Common causes

  • The rotary switch setting for the external emergency stop does not match the parameter setting. p. 312

What to do

  1. AR p. 312
  2. When using external emergency stop: Add 0040h to the normal setting for SV036 or SP041, and set the power supply's rotary switch to "4". p. 312

Before you service the product, read the safety instructions in the manual p. 4.

If 76 is still not resolved

  • contact service / dealer p. 5
    “Wiring, maintenance and inspection work must be done by a qualified technician.”

This page summarises what the manufacturer’s manual says about 76; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.