Mitsubishi Electric MDS-C1 Series Error 37: Initial parameter error

AC Servo/Spindle · taken from the manufacturer’s manual, pages cited

Error code37

An illegal parameter was detected in the parameters received from the NC during power-on, affecting SV001–SV065 or SP001–SP384 settings. The manual's first action is: “PR”

Model
Mitsubishi Electric MDS-C1 Series
Display shows
Initial parameter error (37)
Type
Error code
Source
Manual p. 310

What 37 means

Initial parameter error p. 310

Common causes

  • An illegal parameter was detected in the parameters received from the NC at NC power ON. p. 310
  • SV001 to SV065 (M60S Series: 2201 to 2265) p. 310
  • SP001 to SP384 (M60S Series: 3201 to 3584) p. 310
  • SV104 (M60S Series: 2304) No SHG control operation is provided. p. 310
  • SV105 (M60S Series: 2305) No adaptive filter option is provided. p. 310

What to do

  1. PR p. 310
  2. Set the value within the designated setting range. p. 310
  3. Check SV001, SV002 and SV018. p. 310
  4. Absolute position control cannot be used. To use, change to an absolute position detector. p. 310
  5. SHG control cannot be used. p. 310
  6. The adaptive filter cannot be used. p. 310

Before you service the product, read the safety instructions in the manual p. 4.

If 37 is still not resolved

  • contact service / dealer p. 5
    “Wiring, maintenance and inspection work must be done by a qualified technician.”

This page summarises what the manufacturer’s manual says about 37; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.