Motor encoder signal feedback is abnormal due to poor or wrong wiring, excessive cable length causing voltage drop, or damaged encoder. The manual's first action is: “Check the connector and signal wire welding condition.”
- Model
- GSK GS2000T Series
- Display shows
- The motor encoder signal feedback is abnormal. (Err-9)
- Type
- Alarm code
- Source
- Manual p. 121
What Err-9 means
The motor encoder signal feedback is abnormal. p. 121
Common causes
- 1. Motor encoder signal wire is poorly or wrong connected; p. 121
- 2. The motor encoder signal feedback cable is too long, causing lower signal voltage; p. 121
- 3. The motor encoder is damaged; p. 121
- 4. Servo unit control panel is faulty. p. 121
What to do
- Check the connector and signal wire welding condition. p. 121
- Shorten the cable length within 30m. p. 121
- Change a motor or encoder. p. 121
- Change a servo unit. p. 121
If Err-9 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.