Fault codeErr-17
Braking time is too long due to prolonged excessive input power voltage or excessively large braking resistance causing DC bus voltage rise. The manual's first action is: “Apply a power which meets the working needs of servo unit.”
- Model
- GSK GS2000T Series
- Display shows
- Braking time is too long (Err-17)
- Type
- Fault code
- Source
- Manual p. 122
What Err-17 means
Braking time is too long p. 122
Common causes
- The input power voltage is excessive for a long time. p. 122
- The braking resistance is too large. The energy cannot be released during braking, causing the rise of internal DC voltage. p. 122
What to do
- Apply a power which meets the working needs of servo unit. p. 122
- Change a correct brake resistor. p. 122
If Err-17 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.
This page summarises what the manufacturer’s manual says about Err-17; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with GSK. Found a mistake? Report an error.