Motor's excessive temperature triggers alarm due to prolonged heavy load, frequent start/stop cycles, or damaged motor temperature sensor or fan. The manual's first action is: “Reduce the load or increase the power of the motor and the drive unit.”
- Model
- GSK GS2000T Series
- Display shows
- Err-5
- Type
- Alarm code
- Source
- Manual p. 119
What Err-5 means
Alarm for the motor's excessive temperature (Err-5 alarms when the motor's overheating protection function is used) p. 119
Common causes
- 1. The motor loads for long time; p. 119
- 2. Start/stop frequency is high with heavy load; p. 119
- 3. Check device of the motor's temperature is damaged, or the motor's internal is fault or radiating fan is damaged; p. 119
- 4. Check signal of the motor's temperature is normal and the control plate of the servo unit is fault. p. 119
What to do
- Reduce the load or increase the power of the motor and the drive unit. p. 119
- Reduce start/stop frequency, and improve the motor's radiating condition. p. 119
- Change the motor. p. 119
- Change the drive unit. p. 119
If Err-5 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.