GSK GS2000T Series Error Err-7: The drive prohibition is abnormal (occurs when PA138=1)

AC servo drive unit · taken from the manufacturer’s manual, pages cited

Alarm codeErr-7

Drive prohibition is abnormal because the FSTP/RSTP drive prohibition input terminal is OFF, and this alarm can be shielded if PA138=0. The manual's first action is: “A. Check the connection and 24V power supply of 24V. B. When the drive prohibition function is not used, PA138=0, the alarm is shielded.”

Model
GSK GS2000T Series
Display shows
The drive prohibition is abnormal (occurs when PA138=1) (Err-7)
Type
Alarm code
Source
Manual p. 121

What Err-7 means

The drive prohibition is abnormal (occurs when PA138=1) p. 121

Common causes

  • FSTP,RSTP drive prohibition input terminal is OFF. p. 121

What to do

  1. A. Check the connection and 24V power supply of 24V. B. When the drive prohibition function is not used, PA138=0, the alarm is shielded. p. 121

If Err-7 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.