Motor speed exceeds the setting value of parameter PA54 due to abnormal encoder feedback, incorrect encoder line settings, or control panel fault. The manual's first action is: “Check the motor and encoder and their signal connection state”
- Model
- GSK GS2000T Series
- Display shows
- Motor speed exceeds the setting value of parameter PA54. (Err-1)
- Type
- Alarm code
- Source
- Manual p. 119
What Err-1 means
Motor speed exceeds the setting value of parameter PA54. p. 119
Common causes
- 1. The encoder feedback signal is abnormal; p. 119
- 2. Parameter PA54 (peak speed limit) is set too small or encoder lines setting is smaller than the actual encoder lines; p. 119
- 3. Control panel fault p. 119
What to do
- Check the motor and encoder and their signal connection state p. 119
- Change a servo drive unit. p. 119
If Err-1 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.
This page summarises what the manufacturer’s manual says about Err-1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with GSK. Found a mistake? Report an error.