Alarm codeErr-2
Main circuit DC bus voltage is excessive because the braking resistor is disconnected, damaged, or has an excessive resistance value. The manual's first action is: “Check braking resistor and its connection.”
- Model
- GSK GS2000T Series
- Display shows
- Main circuit DC bus voltage is excessive. (Err-2)
- Type
- Alarm code
- Source
- Manual p. 119
What Err-2 means
Main circuit DC bus voltage is excessive. p. 119
Common causes
- 1. Braking resistor is disconnected or damaged; p. 119
- 2. Braking resistor is unmatched (resistance value is excessive) p. 119
What to do
- Check braking resistor and its connection. p. 119
- A. Change to a new braking resistor whose resistance is matched with the power. B. Reduce the ON/OFF frequency according to actual usage. C. Increase acceleration/deceleration time. p. 119
If Err-2 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.