ABB ACQ810 Error 0004: SHORT CIRCUIT (0x2340)

Pump control drive · taken from the manufacturer’s manual, pages cited

Fault code0004

SHORT CIRCUIT (0x2340) means short-circuit in motor cable(s) or motor. The manual's first action is: “Check motor and motor cable.
Check there are no power factor correction capacitors or surge absorbers in motor cable.”

Model
ABB ACQ810
Display shows
SHORT CIRCUIT (0x2340) (0004)
Type
Fault code
Source
Manual p. 321

What 0004 means

SHORT CIRCUIT (0x2340) p. 321

Common causes

  • Short-circuit in motor cable(s) or motor p. 321

What to do

  1. Check motor and motor cable.
    Check there are no power factor correction capacitors or surge absorbers in motor cable.
    p. 321

Before you service the product, read the safety instructions in the manual p. 195.

If 0004 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact ABB service.

This page summarises what the manufacturer’s manual says about 0004; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.