DEVICE OVERTEMP (0x4210) means measured drive temperature has exceeded internal fault limit. The manual's first action is: “Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against unit power.”
- Model
- ABB ACQ810
- Display shows
- DEVICE OVERTEMP (0x4210) (0003)
- Type
- Fault code
- Source
- Manual p. 321
What 0003 means
DEVICE OVERTEMP (0x4210) p. 321
Common causes
- Measured drive temperature has exceeded internal fault limit. p. 321
What to do
- Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against unit power. p. 321
Before you service the product, read the safety instructions in the manual p. 195.
If 0003 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact ABB service.