ABB ACQ810 Error 0002: DC OVERVOLTAGE (0x3210)

Pump control drive · taken from the manufacturer’s manual, pages cited

Fault code0002

DC OVERVOLTAGE (0x3210) means excessive intermediate circuit DC voltage. The manual's first action is: “Check that overvoltage controller is on, parameter **47.01 Overvolt ctrl**.
Check mains for static or transient overvoltage.
Check deceleration time.
Use coast-to-stop function (if applicable).”

Model
ABB ACQ810
Display shows
DC OVERVOLTAGE (0x3210) (0002)
Type
Fault code
Source
Manual p. 321

What 0002 means

DC OVERVOLTAGE (0x3210) p. 321

Common causes

  • Excessive intermediate circuit DC voltage p. 321

What to do

  1. Check that overvoltage controller is on, parameter **47.01 Overvolt ctrl**.
    Check mains for static or transient overvoltage.
    Check deceleration time.
    Use coast-to-stop function (if applicable).
    p. 321

Before you service the product, read the safety instructions in the manual p. 195.

If 0002 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact ABB service.

This page summarises what the manufacturer’s manual says about 0002; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.