ABB ACQ810 Error 0014: CABLE CROSS CON (0x3181)
Programmable fault: **30.08 Cross connection**

Pump control drive · taken from the manufacturer’s manual, pages cited

Fault code0014

CABLE CROSS CON (0x3181) means incorrect input power and motor cable connection (i.e. input power cable is connected to drive motor connection). The manual's first action is: “Check input power connections.”

Model
ABB ACQ810
Display shows
0014
Type
Fault code
Source
Manual p. 321

What 0014 means

CABLE CROSS CON (0x3181)
Programmable fault: **30.08 Cross connection** p. 321

Common causes

  • Incorrect input power and motor cable connection (i.e. input power cable is connected to drive motor connection). p. 321

What to do

  1. Check input power connections. p. 321

Before you service the product, read the safety instructions in the manual p. 195.

If 0014 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact ABB service.

This page summarises what the manufacturer’s manual says about 0014; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.