Key facts
- Manuals
- 253
- Models
- 17
- Brands
- 30+
- Languages
- ZH · EN
- Last added
- 2026-10-03
Professional medical equipment models by brand
Featured Professional medical equipment manuals

Illumina MiSeqDx Safety and Compliance Guide
This guide provides safety warnings, installation limits, and regulatory compliance statements for the MiSeqDx instrument. It must be read in full before any operation, and only trained Illumina personnel should perform service or maintenance.
Key sections cover general and electrical safety, high‑temperature and heavy‑object warnings, environmental limits, power specifications, and contact information for technical assistance. This manual is written in Chinese.
Covers: Introduction · Safety precautions and symbols · General safety warnings · Electrical safety warnings · High temperature surface safety warning · Heavy object safety warning

OMRON Elepuls HV-F128 Low Frequency Therapy Device User Manual
This manual explains how to safely operate the OMRON Elepuls HV-F128 low‑frequency therapy device. It includes safety warnings, product features, component list, and detailed instructions for battery installation, lead connection, and electrode placement.
The guide also describes the four treatment modes, advanced stimulation settings, storage procedures, troubleshooting steps, and specifications of the device. Proper maintenance and handling of consumable electrode pads are covered to ensure reliable performance. This manual is written in Chinese.
Covers: Safety Precautions · Product Features · Product Components · Part Names and Functions · Battery Installation · Connecting Conductive Leads

TAKAEI TD.I Digital Camera and Image Filing Software User Manual
The manual describes the TAKAEI TD.I digital camera, which uses a 1.45‑megapixel CCD and stores still images as JPEG files of about 100 KB. Images are transferred via an IEEE 1394 cable that also supplies power, and a built‑in yellow filter can improve cornea fluorescence imaging.
The accompanying EyeCAM software provides six scene‑file presets, live preview with adjustable sliders, video capture at 11 fps, and optional trigger functionality using a joystick button on the slitlamp. System requirements include Windows XP, a PCI IEEE 1394 board, and a Pentium IV‑class CPU.
Covers: Camera Overview · System Requirements · Image Filing Software (EyeCAM) · Scene Files and Settings · Trigger and Joystick Operation · Patient Registration

A Tong Mu Medical Imaging Equipment User Manual
The document introduces the A Tong Mu medical imaging equipment, covering its overall structure and the underlying operating principles. It also explains how to correctly use the device and outlines routine maintenance procedures.
Additional information includes copyright details, ISBN numbers, and publication date, indicating that the PDF is a protected digital copy provided by the publisher. This manual is written in Chinese.
Covers: Equipment Structure · Operating Principles · Usage Instructions · Maintenance Procedures · Copyright and Publication Information
Latest Professional medical equipment manuals
Illumina MiSeqDx Safety and Compliance Guide
User Manual 17 pages · 440 KB · ZHSafety and regulatory information for the Illumina MiSeqDx diagnostic instrument.
OMRON Elepuls HV-F128 Low Frequency Therapy Device User Manual
User Manual 16 pages · 4 MB · ZHThe OMRON Elepuls HV-F128 user manual provides safety instructions, setup steps, treatment modes, and maintenance tips for the low‑frequency therapy device.
TAKAEI TD.I Digital Camera and Image Filing Software User Manual
User Manual 4 pages · 585 KB · ENUser manual for the TAKAEI TD.I digital camera and EyeCAM image filing software, covering system requirements, operation, and settings.
A Tong Mu Medical Imaging Equipment User Manual
User Manual 4 pages · 7 KB · ZHThis manual provides an overview of the structure, principles, operation, and maintenance of the A Tong Mu medical imaging equipment.
Tuttnauer 82340M, 2540M, 2540MK Manual Sterilizers Data Sheet
Datasheet 1 pages · 624 KB · ENTechnical specifications and features for Tuttnauer 82340M, 2540M, and 2540MK manual sterilizers.
Radlink GPS 2200 Positioning System User Manual
User Manual 17 pages · 1009 KB · ENThe Radlink GPS 2200 Positioning System User Manual provides setup, operation, and maintenance instructions for the orthopedic imaging system.
Leica HistoCore PEGASUS Plus Automatic Tissue Dehydrator User Manual
User Manual 188 pages · 12.4 MB · ZHThe manual provides safety information, installation steps, operation procedures, program and reagent settings, and maintenance guidelines for the Leica…
Hamilton C3 Quick Start Guide
Quick Start Guide 40 pages · 4.4 MB · ZHQuick reference guide for the Hamilton C3 ventilator covering basics, setup, testing, patient ventilation, monitoring, alarms and control parameters.
TobiiDynavox I-Series I-110 User Manual
User Manual 30 pages · 2.5 MB · ZHThe manual provides setup, operation, safety, maintenance, and specifications for the TobiiDynavox I-Series I-110 speech‑generating device.
AXYGEN GD-1000/GDBL-1000 Gel Imaging System Installation Guide
Installation Guide 10 pages · 722 KB · ZHThe AXYGEN GD-1000/GDBL-1000 gel imaging system installation guide provides setup steps, software installation, image capture, and optional accessories.
OneGuide Computer Guided Surgery System Product Leaflet
Product Leaflet 2 pages · 2.9 MB · ENThe OneGuide Computer Guided Surgery System shortens drilling steps, enables precise, fast, low‑heat dental implant surgery.
Pentax EG-290Kp / EC-380LKp Video GI Endoscope Owner's Manual
User Manual 52 pages · 1.7 MB · ENOwner's manual for Pentax EG-290Kp and EC-380LKp video GI endoscopes covering use, preparation, care and specifications.
Integra CUSA Excel / CUSA Excel+ User Manual
User Manual 195 pages · 5.8 MB · ENUser guide for the Integra CUSA Excel and CUSA Excel+ ultrasonic surgical aspirator system, covering setup, operation, safety and maintenance.
Synthes AO ASIF Screw Reference Chart
Product Leaflet 4 pages · 897 KB · ENReference chart from Synthes showing screw, drill bit, tap, and guide wire dimensions for AO/ASIF orthopedic implants.
Tissue‑Tek Cryo3 Flex Microtome Cryostat Product Leaflet
Product Leaflet 4 pages · 1.3 MB · ENThe Tissue‑Tek Cryo3 Flex microtome/cryostat product leaflet describes its configurations, key features, and accessories for fast frozen sectioning.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Quick Start Guide
The shortest path to a working setup, usually only a few pages.
Installation Guide
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in Professional medical equipment manuals
How do I install the batteries?
Open the back cover, insert two 4‑size alkaline batteries as shown, then close the cover.
From: OMRON Elepuls HV-F128 Low Frequency Therapy Device User Manual
How long does the device run before it shuts off automatically?
The device automatically turns off after 15 minutes of continuous treatment.
From: OMRON Elepuls HV-F128 Low Frequency Therapy Device User Manual
What cable is used for image data transfer?
An IEEE 1394 (FireWire) cable is used for high‑speed image transfer and also supplies power to the camera.
From: TAKAEI TD.I Digital Camera and Image Filing Software User Manual
How many scene files can be saved for different exposure settings?
Settings can be saved in six different scene files, each optimized for a specific region or iris color.
From: TAKAEI TD.I Digital Camera and Image Filing Software User Manual
What is the ISBN‑13 of this manual?
The ISBN‑13 is 9787117042338.
When was this manual published?
It was published on 2001‑10‑1.
