Featured Beckman manuals

Beckman Vi-CELL Cell Counting Reagent Manual
This manual describes the cell counting reagent (product code BTN131200) designed for the Beckman Vi-CELL Viability Analyzer. The kit includes staining solution, cleaning solution, buffer, disinfectant, and a printed instruction sheet, providing enough reagents for up to 100 samples.
The document explains how to select cell types in the Vi-CELL software, how to operate the instrument, and the analytical range (cell diameter 5‑70 µm, concentration 5×10⁴‑1×10⁷ cells/mL, viability 20‑100%). Storage conditions are room‑temperature transport, 4 °C storage, with a one‑year shelf life. Safety notes warn about 70 % isopropanol and 0.4 % trypan blue, and advise against ingestion, inhalation, reuse, or freezing. This manual is written in Chinese.
Covers: 产品编号 · 规格及成分 · 保存条件 · 使用方法 · 细胞类型的设定与存取 · 仪器的操控

Beckman P/ACE MDQ Capillary Electrophoresis Instrument Operating Instructions
The guide describes how to power on the instrument, load reagents, edit methods, create sequences, and run a single analysis. It also shows how to use the 32 Karat software to control the instrument and monitor the detector.
Additional sections cover quartz capillary preparation, safety precautions during high‑voltage operation, and the proper shutdown procedure to protect the device and the user. This manual is written in Chinese.
Covers: Power On · Quartz Capillary Treatment · Method Editing · Sequence Creation · System Operation · Shutdown

Beckman Coulter T8-RD1 User Manual
The T8‑RD1 kit contains a mixture of monoclonal antibodies labeled with Phycoerythrin (PE) that target the CD8 antigen on T‑cells. Each test vial provides 0.05‑0.5 µg of antibody and includes reagents such as BSA (0.2 %), NaCl (0.15 M), and azide (0.1 %). The kit is intended for flow‑cytometric analysis of lymphocyte surface antigens and measurement of suppressor T‑cell activity.
The manual describes how to prepare samples, perform the immunofluorescence reaction, and acquire data on a flow cytometer with at least four detection channels. It includes detailed precautions (e.g., do not use with a light microscope, handle azide with care), storage instructions (refrigerated 2‑8 °C, protect from light), and interpretation guidelines for CD8‑positive cell percentages and absolute counts. This manual is written in Japanese.
Covers: General Precautions · Kit Composition · Intended Use · Measurement Principle · Operational Precautions · Reagent Preparation and Usage
Latest Beckman manuals
Beckman Vi-CELL Cell Counting Reagent Manual
User Manual 2 pages · 115 KB · ZHInstructions and specifications for Beckman Vi-CELL cell counting reagent, compatible with the Vi-CELL Viability Analyzer.
Beckman P/ACE MDQ Capillary Electrophoresis Instrument Operating Instructions
User Manual 3 pages · 66 KB · ZHThis manual provides step‑by‑step operating instructions for the Beckman P/ACE MDQ capillary electrophoresis instrument.
Beckman Coulter T8-RD1 User Manual
User Manual 4 pages · 296 KB · JAThe Beckman Coulter T8‑RD1 manual provides instructions, safety warnings, and assay procedures for the CD8 (T8) PE‑labeled antibody kit used in flow cytometry.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Beckman manuals
How many samples can one reagent kit support?
Each kit provides enough reagents for 100 samples.
What are the recommended storage conditions?
Transport at room temperature, store at 4 °C, and use within one year.
How do I start the Beckman P/ACE MDQ instrument?
Connect the power, turn on the instrument switch, start the computer, click the 32 Karat software icon, then click the PAD detector icon to enter the control interface.
From: Beckman P/ACE MDQ Capillary Electrophoresis Instrument Operating Instructions
What safety precaution must be observed while the instrument is running?
Do not open the tray cover during operation because the instrument generates high voltage.
From: Beckman P/ACE MDQ Capillary Electrophoresis Instrument Operating Instructions
What is the intended use of the T8‑RD1 kit?
It is used to analyze lymphocyte surface antigens and measure suppressor T‑cell (CD8) activity by flow cytometry.
What are the storage conditions for the kit?
Store the unopened kit refrigerated at 2‑8 °C, protect from strong light, and do not freeze.