VICOR 2VOUT Manuals

ManualLib has 3 documents for the VICOR 2VOUT: 2 user manuals, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 2Datasheet 1

Key facts

Brand
VICOR
Model
2VOUT
Industry
Industrial
Documents
3
Languages
EN
Last added
2012-06-08

Start here

VICOR 375Vin 2Vout 160Watts DC-DC Converter Module handbook

VICOR 375Vin 2Vout 160Watts DC-DC Converter Module handbook

User Manual 8 pages · 194 KB · EN

The V375A2C160A is a high‑density 375 Vin / 2 Vout DC‑DC converter delivering up to 160 W. It is intended for distributed power, off‑line systems with PFC front‑ends, and electric vehicle applications.

This handbook covers the module’s electrical and mechanical specifications, pin‑level control functions (PC, SC, PR), parallel operation, wiring diagrams, and mounting details, along with safety and regulatory information.

Read online

VICOR 2VOUT specifications

Input Voltage Range-0.5 to +36.0 Vdc
Output Voltage2V (Nominal)
Maximum Output Power160 Watts
Efficiency (Typical)71.6%
Maximum Operating Temperature100°C
Isolation Voltage (In to Out)3000 Vrms

Source: VICOR 24Vin 2Vout 160Watts DC-DC Converter Module See Page 8 for Part Numbers Options

All VICOR 2VOUT documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the input surge withstand capability?

The module can withstand an input surge of 50V for less than 100ms.

From: VICOR 24Vin 2Vout 160Watts DC-DC Converter Module See Page 8 for Part Numbers Options

Can the output voltage be programmed?

Yes, the output is programmable from 10% to 110% of the nominal voltage.

From: VICOR 24Vin 2Vout 160Watts DC-DC Converter Module See Page 8 for Part Numbers Options

What is the programming range for the output voltage?

The output voltage can be programmed from 10% to 110% of the nominal value.

From: VICOR 300Vin 2Vout 50Watts DC-DC Converter Module Model Number V300C2C50A

What happens if an internal fault occurs?

The module contains watchdog circuitry that monitors parameters; if a fault like overtemperature occurs, the module shuts down and the PC signal goes low.

From: VICOR 300Vin 2Vout 50Watts DC-DC Converter Module Model Number V300C2C50A

What is the input voltage range of the V375A2C160A?

The module operates from 250 V to 425 V input.

From: VICOR 375Vin 2Vout 160Watts DC-DC Converter Module handbook

What is the maximum output power the converter can deliver?

It can deliver up to 160 W when the baseplate is at 100 °C.

From: VICOR 375Vin 2Vout 160Watts DC-DC Converter Module handbook