Rockwell Automation Kinetix 5700 Servo Drive User Manual
This manual covers safety requirements, installation steps, wiring guidelines, and configuration procedures for the Kinetix 5700 servo drive system. It emphasizes that all work must be performed by suitably trained personnel and in compliance with applicable codes, laws, and standards.
The document is organized into chapters that detail system planning, mounting, connector data, power‑supply configuration, drive startup, troubleshooting, module replacement, and the Safe Torque‑off safety feature. Detailed diagrams, pinout tables, and example wiring layouts support the implementation and maintenance of the drive system.
Rockwell Automation Kinetix 5700 specifications
| Continuous Output Power (2198-P031) | 0.5 kW |
|---|---|
| Continuous Output Current (2198-P031) | 10.5 A |
| Continuous Output Power (2198-P070) | 25.5 kW |
| Continuous Output Current (2198-P070) | 37.3 A |
| Continuous Output Power (2198-P141) | 46.9 kW |
| Continuous Output Current (2198-P141) | 69.2 A |
| Continuous Output Power (2198-P208) | 69.2 kW |
| Continuous Output Current (2198-P208) | 105.0 A |
Source: Rockwell Automation Kinetix 5700 DC Bus Power Supply Installation Guide
All Rockwell Automation Kinetix 5700 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Rockwell Automation Kinetix 5700 Safety Monitor User Manual 126 p
- Rockwell Automation Kinetix 5700 Servo Drive User Manual 276 p
- Rockwell Automation Kinetix 5700 Servo Drive User Manual 383 p
- Rockwell Automation Kinetix 5700 Servo Drives User Manual 363 p
- Rockwell Automation Kinetix 5700 Servo Drive User Manual 465 p
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What applications is the Kinetix 5700 drive described for?
It is described for Safety Integrity Level (SIL 3) and Performance Level (PL e) applications.
From: Rockwell Automation Kinetix 5700 Safety Monitor User Manual
What safety functions does the Kinetix 5700 drive have?
It has safe stop and safe monitoring functions.
From: Rockwell Automation Kinetix 5700 Safety Monitor User Manual
Who should perform the installation and maintenance of this equipment?
Installation, adjustment, activation, utilization, assembly, disassembly, and maintenance must be performed by properly trained personnel in accordance with applicable practice codes.
From: Rockwell Automation Kinetix 5700 Servo Drive User Manual
When should the grounding screw be removed from the DC bus power supply?
The grounding screw should be removed if using ungrounded, corner-grounded, or impedance-grounded power configurations.
From: Rockwell Automation Kinetix 5700 DC Bus Power Supply Installation Guide
What is the recommended minimum cabinet depth for installation?
The recommended minimum cabinet depth is 300 mm (11.81 in.).
From: Rockwell Automation Kinetix 5700 DC Bus Power Supply Installation Guide
Do I need to remove ground screws for a grounded Y-type power configuration?
No, you do not need to remove the screws if using a grounded Y-type power distribution system.
From: Rockwell Automation Kinetix 5700 Power Module Installation Guide