Start here

Rockwell Automation Guardmaster 440G-LZ User Manual
This manual provides step-by-step instructions for installing, wiring, and troubleshooting the Guardmaster 440G-LZ guard locking switch. It includes safety guidelines, wiring diagrams, and technical specifications. The switch uses RFID coding and a bi-stable solenoid to lock guards in place, with OSSD outputs enabled only when the guard is both closed and locked. It is designed for use in safety-critical applications with compliance to IEC 60947-5-3, IEC 61508, and ISO 13849-1 standards.
The manual covers assembly, mounting, actuator alignment, LED diagnostics, and troubleshooting. It also includes specifications such as safety ratings, operating characteristics, and environmental protection. The device is suitable for applications requiring PLe Category 4 or SIL 3 safety levels.
Rockwell Automation Guardmaster 440G-LZ specifications
| Safety Ratings | IEC 60947-5-3, IEC 60947-5-1, IEC 61508, EN ISO 13849-1, IEC 62061, EN/ISO14119, UL 508 |
|---|---|
| Safety Classification | Guard door sensing and lock monitoring PLe Category 4 per ISO 13849-1, SIL 3 per IEC 61508 and IEC 62061 |
| Functional Safety Data | Guard door sensing and lock monitoring PFHD: 9.1 x 10-10 |
| Mission Time/PTI | 20 years |
All Rockwell Automation Guardmaster 440G-LZ documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What safety standards does the Guardmaster 440G-LZ comply with?
It complies with IEC 60947-5-3, IEC 60947-5-1, IEC 61508, EN ISO 13849-1, IEC 62061, EN/ISO14119, and UL 508.
What is the safety classification of the Guardmaster 440G-LZ?
It is classified as PLe Category 4 per ISO 13849-1 and SIL 3 per IEC 61508 and IEC 62061.
What does the Guardmaster 440G-LZ guard locking switch do?
It extends a locking bolt from the switch through a hole in the actuator to prevent the guard from opening. The locking bolt is allowed to extend only when the corresponding actuator is detected within range.
From: Rockwell Automation Guardmaster 440G-LZ Guard Locking Switch User Manual
When are the OSSD outputs enabled?
They are enabled only when the locking bolt is sensed in its extended position in the actuator, which occurs when the guard is closed and locked.
From: Rockwell Automation Guardmaster 440G-LZ Guard Locking Switch User Manual