Mitsubishi电机伺服放大器MR-J5-G-N1/MR-J5W-G-N1 user manual, introduces the installation, wiring, setting, adjustment, operation and maintenance of the servo amplifier.
This is the Chinese-language user manual (communication and functions volume, 用户手册 通信和功能篇) for the Mitsubishi Electric MR-J5-G-N1 and MR-J5W-G-N1 AC servo amplifiers. It explains how the servo amplifier operates as an EtherCAT slave following the CAN application protocol over EtherCAT (CoE) standard, with device type "drives" supporting the CiA 402 Drive Profile.
The manual covers supported control modes (cyclic synchronous position, velocity and torque; profile position, velocity and torque; homing), EtherCAT state machine, object dictionary, PDO and SDO communication, synchronization modes, CiA 402 drive profile state machines and controlwords, startup procedures including the absolute position detection system and Ethernet cable connection, and vendor-specific functions such as torque limit selection. It also includes safety precautions and describes the related e-Manual documentation set available from the Mitsubishi Electric FA website. This manual is written in Chinese.
| Fieldbus | EtherCAT (CoE), slave |
|---|---|
| Device profile | CiA 402 Drive Profile |
| Control modes | csp, csv, cst, pp, pv, tq, hm |
| Cyclic synchronous position mode | Receives position commands at fixed cycles; absolute position address required |
| Profile position mode | Positioning control with absolute or relative position addresses |
It operates as an EtherCAT slave following the CAN application protocol over EtherCAT (CoE) standard, with device type "drives" supporting the CiA 402 Drive Profile.
It supports cyclic synchronous position (csp), velocity (csv) and torque (cst) modes, profile position (pp), velocity (pv) and torque (tq) modes, and homing mode (hm).
The latest e-Manual and PDF manuals can be downloaded from the Mitsubishi Electric FA website at www.MitsubishiElectric.co.jp/fa.
Wait at least 15 minutes after turning off the power before performing wiring or inspection, otherwise electric shock may occur.