Key facts
- Brand
- ifm
- Model
- PK652X
- Category
- Industrial Supply
- Industry
- Industrial
- Documents
- 2
- Languages
- ZH
- Last added
- 2011-10-26
Start here

ifm PK652X Electronic Pressure Monitor Installation Guide
This document is an installation manual for the ifm PK652X electronic pressure monitor. It provides instructions on safety precautions, functional characteristics, and the installation process. The guide details how to connect the device electrically and how to set the pressure switching values using the adjustment rings. This manual is written in Chinese.
Read onlineifm PK652X specifications
| Supply Voltage | 9.6...32 DC |
|---|---|
| Rated Current | 500 mA |
| Switching Frequency | 100 Hz |
| Setting Accuracy | < ± 2.5 % |
| Operating Temperature | -25...80 °C |
| Protection Class | IP 67 |
| Housing Material | Pocan; PC; FPM; Stainless Steel |
Source: ifm PK652X Electronic Pressure Monitor Installation Guide
All ifm PK652X documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What is the minimum hysteresis between set and reset values?
The minimum difference between the set and reset values is 2% of the measurement range end value.
From: ifm PK652X Electronic Pressure Monitor Installation Guide
What is the tightening torque for the pipe connection?
The tightening torque for the pipe connection is 25 Nm.
From: ifm PK652X Electronic Pressure Monitor Installation Guide
What is the required tightening torque for the pipe connection?
The pipe connection must be tightened to a torque of 25 Nm.
From: PK652x704880 Electronic Pressure Monitor Installation Manual
What is the protection rating of the device?
The device has an IP67 protection rating.
From: PK652x704880 Electronic Pressure Monitor Installation Manual