About this manual

This document is an installation manual for the ifm PK652X electronic pressure monitor. It provides instructions on safety precautions, functional characteristics, and the installation process. The guide details how to connect the device electrically and how to set the pressure switching values using the adjustment rings. This manual is written in Chinese.

What's inside

  • Safety Instructions
  • Functions and Characteristics
  • Installation
  • Electrical Connections
  • Settings and Operation
  • Technical Data
  • Dimensions

Specifications

Supply Voltage9.6...32 DC
Rated Current500 mA
Switching Frequency100 Hz
Setting Accuracy< ± 2.5 %
Operating Temperature-25...80 °C
Protection ClassIP 67
Housing MaterialPocan; PC; FPM; Stainless Steel

Frequently asked questions

What is the minimum hysteresis between set and reset values?

The minimum difference between the set and reset values is 2% of the measurement range end value.

What is the tightening torque for the pipe connection?

The tightening torque for the pipe connection is 25 Nm.