Key facts
- Brand
- ifm
- Model
- PA90XX
- Documents
- 2
- Languages
- SV
- Last added
- 2011-11-09
Start here

ifm PA30xx PA90xx Electronic Pressure Sensor Mounting Instructions
This Swedish mounting instruction covers the ifm electronic PA30xx/PA90xx electronic pressure sensors. It includes safety instructions, intended use, mounting, electrical connection, technical data and a dimension drawing.
The document states that the sensors measure relative pressure and convert it to an analog output signal: 4 ... 20 mA for PA30xx and 0 ... 10 V for PA90xx. It also lists pressure ranges, overload pressures, bursting pressures, supply voltages, environmental temperatures and protection classes. This manual is written in Swedish.
ifm PA90XX specifications
| PA30xx operating voltage | 9.6 ... 32 V DC |
|---|---|
| PA30xx analog output | 4 ... 20 mA |
| PA90xx operating voltage | 16 ... 32 V DC |
| PA90xx analog output | 0 ... 10 V |
| Ambient temperature | -25 ... +80 °C |
| Media temperature | -25 ... +90 °C |
| Protection class | IP 68 / IP 69K for PAxxx0 ... PAxxx2 and PAxx60; IP 65 for PAxxx3 ... PAxxx9 |
Source: ifm PA30xx PA90xx Electronic Pressure Sensor Mounting Instructions
All ifm PA90XX documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What is the maximum pressure for gaseous media?
When gaseous pressure media are used, the pressure may be max. 25 bar.
From: ifm PA30xx PA90xx Electronic Pressure Sensor Mounting Instructions
What analog output does the PA30xx provide?
The PA30xx provides a 4 ... 20 mA analog output.
From: ifm PA30xx PA90xx Electronic Pressure Sensor Mounting Instructions