Haier YR0059 YD1059 Water Dispenser User Manual
This manual provides instructions for installing, operating, and maintaining Haier water dispensers model YR0059 and YD1059. It covers safety precautions, proper use of hot, warm, cold and room‑temperature water, and details the warranty and service contact information.
The guide also includes cleaning procedures, anti‑scale tips, storage recommendations, troubleshooting of common faults, and a full list of technical parameters such as power ratings, water capacities and environmental limits. This manual is written in Chinese.
Haier YR0059 specifications
| Model | YR0059 / YD1059 |
|---|---|
| Rated total power | 1200 W (YR0059) / 1265 W (YD1059) |
| Rated heating power | 1200 W |
| Power consumption (24 h) | 0.3 kWh (heat) / 0.6 kWh (cool) |
| Heating water capacity | 10 L |
| Cooling water capacity | 0.5 L |
| Protection type | Class I / Class II |
| Ambient humidity range | ≤90 % RH |
| Ambient temperature range | 10 °C‑38 °C (heat) / 16 °C‑32 °C (cool) |
All Haier YR0059 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What type of water should be used in the dispenser?
Only bottled purified water should be used; using mineral water may cause scale buildup in the heating tank.
What should I do if the dispenser does not produce hot water?
Check that the power plug is fully inserted, the power switch is on, and the heating indicator light is lit; also verify that the water level is above the minimum.
What type of water can be used in the dispenser?
Only bottled purified water should be used; using mineral water may cause scale buildup in the heating tank.
From: Haier YR0059/YD1059 Drinking Water Machine User Manual
How should the machine be cleaned regularly?
After the machine runs for 30 minutes, turn off the power, open the drain plug, empty the water, then close the plug. For scale removal, fill the tank with 2 % food‑grade citric acid solution, run for 30 minutes, drain, and rinse with purified water.