Endress+Hauser FMU30 Manuals

ManualLib has 2 documents for the Endress+Hauser FMU30 (Ultrasonic level meter): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Model
FMU30
Industry
Industrial
Documents
2
Languages
ZH
Last added
2026-11-19

Start here

Endress+Hauser Prosonic T FMU30 Ultrasonic Level Measurement Operating Manual

Endress+Hauser Prosonic T FMU30 Ultrasonic Level Measurement Operating Manual

User Manual 60 pages · 2.5 MB · ZH

This operating manual describes the installation and commissioning of the Endress+Hauser Prosonic T FMU30 ultrasonic level transmitter. It covers the functions needed for routine measurement operation, while additional parameters such as measurement point optimization and measured value conversion are referenced to the separate instrument function description.

The document includes safety guidance, identification and ordering information, installation and wiring, operation via the local display or FieldCare, basic calibration, envelope curve evaluation, troubleshooting, maintenance and repair, accessories, and technical specifications. This manual is written in Chinese.

Read online

Endress+Hauser FMU30 specifications

Measurement principleContinuous, non-contact level measurement
Maximum range, liquids8 m (26 ft)
Maximum range, solids3.5 m (11 ft)
Output signal4...20 mA
Supply voltage14...35 V
Power consumption51...800 mW
Terminal cable cross-section0.25...2.5 mm (20...14 AWG)
Cable entryM20x1.5 cable gland, G½ or ½ NPT
Protection ratingIP68
Sensor options1½" or 2" sensor
Blind distance, 1½" sensor0.25 m
Blind distance, 2" sensor0.35 m
Measured variableDistance D between sensor diaphragm and material surface

Source: Endress+Hauser Prosonic T FMU30 Ultrasonic Level Measurement Operating Manual

All Endress+Hauser FMU30 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the maximum measuring range of the Prosonic T FMU30?

The maximum range is 8 m (26 ft) for liquids and 3.5 m (11 ft) for solids, depending on the sensor used.

From: Endress+Hauser Prosonic T FMU30 Ultrasonic Level Measurement Operating Manual

What output signal does the FMU30 provide?

The instrument provides a 4...20 mA output signal, with an adjustable current output and an alarm signal shown on the local display.

From: Endress+Hauser Prosonic T FMU30 Ultrasonic Level Measurement Operating Manual

How far from the tank wall should the FMU30 sensor be mounted?

The recommended distance between the sensor and the tank wall is about 1/6 of the tank diameter, and the sensor should not be mounted in the center of the tank.

From: Endress+Hauser Prosonic T FMU30 Ultrasonic Level Transmitter Brief Operating Guide

Can two ultrasonic measuring devices be installed on the same tank?

No, the guide states that two ultrasonic measuring devices must not be installed on the same tank because the two signals may interfere with each other.

From: Endress+Hauser Prosonic T FMU30 Ultrasonic Level Transmitter Brief Operating Guide