Endress+Hauser PMC51, PMP51, PMP55 Manuals

ManualLib has 2 documents for the Endress+Hauser PMC51, PMP51, PMP55 (Industrial Supply): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Model
PMC51, PMP51, PMP55
Industry
Industrial
Documents
2
Languages
EN
Last added
2026-11-12

Start here

Endress+Hauser MPMC51/PMP51/PMP55 Pressure Transmitter Brief Operating Instructions

Endress+Hauser MPMC51/PMP51/PMP55 Pressure Transmitter Brief Operating Instructions

User Manual 28 pages · 790 KB · EN

These brief operating instructions provide essential information for the Endress+Hauser Cerabar M series pressure transmitters (MPMC51, PMP51, PMP55). They outline safety requirements, identification, installation steps, electrical connections, operation, and commissioning procedures.

The document is intended for qualified personnel who will install, commission, and maintain the devices. It references detailed operating instructions and additional documentation available via the Endress+Hauser device viewer for complete technical data.

Read online

Endress+Hauser PMC51, PMP51, PMP55 specifications

Output signal4…20 mA analog
Thread type (G 1 1/2)G 1 1/2 thread
Maximum torque (NPT threads)20–30 Nm (14.75–22.13 lbf ft)
Maximum torque (PVDF thread)7 Nm (5.16 lbf ft)
Weight limitup to 18 kg

Source: Endress+Hauser MPMC51/PMP51/PMP55 Pressure Transmitter Brief Operating Instructions

All Endress+Hauser PMC51, PMP51, PMP55 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the designated use of the Cerabar M?

The Cerabar M is a pressure transmitter used for measuring pressure and level.

From: Endress+Hauser Cerabar M PMC51/PMP51/PMP55 Brief Operating Instructions

Who is qualified to install, connect, commission, and maintain the device?

The device must only be installed, connected, commissioned, and maintained by qualified and authorized specialists, such as electrical technicians.

From: Endress+Hauser Cerabar M PMC51/PMP51/PMP55 Brief Operating Instructions

What is the output signal of the Cerabar M pressure transmitters?

The devices provide a 4 to 20 mA analog output signal.

From: Endress+Hauser MPMC51/PMP51/PMP55 Pressure Transmitter Brief Operating Instructions

What safety step must be taken before connecting the device?

The supply voltage must be switched off before any electrical connection is made.

From: Endress+Hauser MPMC51/PMP51/PMP55 Pressure Transmitter Brief Operating Instructions