Endress+Hauser Gammapilot M FMG60 HART Radiometric Measuring Device Brief Operating Instructions

Endress+Hauser Gammapilot M FMG60 HART Radiometric Measuring Device Brief Operating Instructions

Quick Start Guide 60 pages · 2.4 MB · ZH

The Gammapilot M FMG60 HART is an integral transmitter for non-contact level, limit, density and concentration measurement. A single unit has a maximum measuring range of 2 m (6.6 ft), which can be extended by cascading several units; for limit detection it is certified to IEC 61508 up to SIL2/3.

This Chinese brief operating instructions covers safety, radiation protection, installation, wiring, operation and commissioning, including calibration for level/limit and density/concentration. It states that it does not replace the operating manual supplied with the device and refers readers to the CD or www.endress.com/deviceviewer for further documentation. This manual is written in Chinese.

Read online

Endress+Hauser FMG60 specifications

Measurement variablesNon-contact level, limit, density and concentration
Maximum measuring range, single unit2 m (6.6 ft)
Safety integrity level, limit detectionSIL2/3
Storage temperature, PVT scintillator version-40...+50 °C (-40...+122 °F)
Storage temperature, NaI crystal version-40...+60 °C (-40...+140 °F)
Output current range4...20 mA

Source: Endress+Hauser Gammapilot M FMG60 HART Radiometric Measuring Device Brief Operating Instructions

All Endress+Hauser FMG60 documents by type

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

Questions answered in these manuals

What measurements can the Gammapilot M FMG60 perform?

It is used for non-contact level, limit, density and concentration measurement.

From: Endress+Hauser Gammapilot M FMG60 HART Radiometric Measuring Device Brief Operating Instructions

What is the maximum measuring range of one Gammapilot M?

One unit has a maximum measuring range of 2 m (6.6 ft); cascading several units can extend the range.

From: Endress+Hauser Gammapilot M FMG60 HART Radiometric Measuring Device Brief Operating Instructions

What can the Gammapilot MFMG60 measure?

It performs non-contact limit detection, level, interface and density measurement.

From: Endress+Hauser Gammapilot MFMG60 Radiation Instrument Technical Information

Can it be used in explosive atmospheres?

Yes, the instrument is suitable for use in explosive atmospheres.

From: Endress+Hauser Gammapilot MFMG60 Radiation Instrument Technical Information