Endress+Hauser FMI51, FMI52 Capacitive Level Transmitter Operating Instructions
The Liquicap M FMI51 and FMI52 are compact capacitive level transmitters designed for continuous measurement of liquids. The manual provides safety instructions, designated use, and guidelines for safe installation and commissioning, emphasizing the need for trained personnel.
It details installation steps, wiring recommendations, operation options, troubleshooting, and technical data such as capacitance values, measuring frequency, output signal, and probe specifications. Accessories, maintenance procedures, and commissioning menus are also described.
Endress+Hauser FMI51/FMI52 specifications
| Application | Continuous level measurement |
|---|---|
| Material operating temperature range | -80 to +200 °C |
| Overpressure capability | Up to 100 bar |
| Vacuum service | Suitable for vacuum measurement |
| Conductivity for calibration-free operation | 100 μS/cm or higher |
| Ambient temperature range with F16 housing | -40 to +70 °C |
| Climate class | DIN EN 60068-2-38/IEC 68-2-38, Z/AD test |
| Vibration | 20 Hz to 2000 Hz, 0.01 g²/Hz |
| Shock | 30 g acceleration |
| EMC emissions | EN 61326, Class B |
| Fault current (FEI50H) | 22 mA |
Source: Endress+Hauser Liquicap M FMI51/FMI52 Capacitive Level Measuring Instrument Technical Information
All Endress+Hauser FMI51/FMI52 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the Liquicap M FMI51/FMI52 used for?
It is an integrated transmitter for continuous level measurement.
From: Endress+Hauser Liquicap M FMI51/FMI52 Capacitive Level Measuring Instrument Technical Information
Does it require calibration for conductive media?
No calibration is required when the medium conductivity is 100 μS/cm or higher.
From: Endress+Hauser Liquicap M FMI51/FMI52 Capacitive Level Measuring Instrument Technical Information
What is the recommended torque for flange bolts?
The recommended torque is 60 to 100 Nm.
From: Endress+Hauser FMI51, FMI52 Capacitive Level Transmitter Operating Instructions
What is the basic capacitance of the probe?
The basic capacitance is approximately 18 pF.
From: Endress+Hauser FMI51, FMI52 Capacitive Level Transmitter Operating Instructions