Endress+Hauser Gammapilot M FMG60 HART Radiometric Measuring Device Brief Operating Instructions

This document mainly introduces the features and specifications of the Gammapilot M FMG60 HART 2 Endress+Hauser product.


Endress+Hauser Gammapilot M FMG60 HART Radiometric Measuring Device Brief Operating Instructions - cover page
Brand
Endress+Hauser
Category
Other
Document type
Quick Start Guide
Language
Chinese
Pages
60
File format
PDF
File size
2.4 MB
Published
08 November, 2023
Updated
08 November, 2023
Model
FMG60
MD5 checksum
6392EE8DB3288CCBB9ACB212BF6BC406

About this manual

The Gammapilot M FMG60 HART is an integral transmitter for non-contact level, limit, density and concentration measurement. A single unit has a maximum measuring range of 2 m (6.6 ft), which can be extended by cascading several units; for limit detection it is certified to IEC 61508 up to SIL2/3.

This Chinese brief operating instructions covers safety, radiation protection, installation, wiring, operation and commissioning, including calibration for level/limit and density/concentration. It states that it does not replace the operating manual supplied with the device and refers readers to the CD or www.endress.com/deviceviewer for further documentation. This manual is written in Chinese.

What's inside

  • Safety instructions
  • Radiation protection
  • Installation
  • Wiring
  • Operation
  • Commissioning
  • Calibration of level and limit detection
  • Calibration of density and concentration measurement
  • SIL locking

Specifications

Measurement variablesNon-contact level, limit, density and concentration
Maximum measuring range, single unit2 m (6.6 ft)
Safety integrity level, limit detectionSIL2/3
Storage temperature, PVT scintillator version-40...+50 °C (-40...+122 °F)
Storage temperature, NaI crystal version-40...+60 °C (-40...+140 °F)
Output current range4...20 mA

Frequently asked questions

What measurements can the Gammapilot M FMG60 perform?

It is used for non-contact level, limit, density and concentration measurement.

What is the maximum measuring range of one Gammapilot M?

One unit has a maximum measuring range of 2 m (6.6 ft); cascading several units can extend the range.

What safety integrity level is possible for limit detection?

For limit detection the device is certified to IEC 61508 up to SIL2/3.

How are measured values output?

Measured values are output via current output and HART signal.